December 2008 Page 1–21
Chapter 1. Product Description
1
Table 1–19b. SRD-4 Specifications.
Catalog ID FCA
Interface One (1) RS-232C
One RJ-45 ethernet
Protocol 10/100 Base T
Indicators TX LED
RX LED
Trap Enabled
Connector DB9 female
RJ-45
Power 4.2 Watts Max.
Consumption
Operating 700mA at 6V
Current
Table 1–20.
FCA Module Specifications
Table 1–19c. SRD-4N Specifications.
1.25.17 FOCUS Communications
Agent (FCA) Module
Feature Specification
Catalog ID F020SRDMN-002 (SRD-4)
Interfaces Two (2) RS-232 (sub-chan. A&B)
Two (2) RS-485 (sub-chan. C&D)
(One RS-232, RS-485 each DS0)
Handshaking RTS, CTS
Supported (232 only)
Data Rate 0 to 9600 bps asynchronous
Indicators TX per channel
RX per channel
Module Status LED
Connectors Two (2) DB9 Female (232) DCE
Terminal Block (485)
Feature Specification
Catalog ID F020SRDMN-003 (SRD-4N)
Interfaces Two (2) RS-232 (sub-chan. A&B)
Two (2) RS-485 (sub-chan. C&D)
full duplex and DNP Support
Handshaking RTS, CTS
Data Rate 0 to 9600 bps asynchronous
Indicators TX per channel
RX per channel
Module Status LED
Connectors Two (2) DB9 Female (232) DCE
Terminal Block (485)
labeled ‘C’, (D unused)